Type 021N
Identification
- Has disk-shaped cells
- Gram negative
- Has no attached growth or sheath
Why Do I Have It?
- Nitrogen deficiency
Effects on Wastewater System
Type 021N can cause bulking when present in high abundance.
Treatment
To treat Type 021N a nitrogen supplement, such as Accelerator 7, is recommended. Accelerator 7 is an amino acid-based organic source of highly bioavailable nitrogen. Increasing aeration to raise the oxidation/reduction potential in a wastewater system can help with control of this filament. If this is not possible, the addition of OxyFresh can assist in increasing oxidation/reduction potential to limit Low D.O. conditions.
Do not chlorinate Type 021N; this filament is very resilient to chlorination. Chlorination will frequently increase the filament’s abundance.
Under the Microscope and in Your Plant
Type 021N is a thick (1.6-2.5 µm) filament that ranges from 500-1,000 µm in length. This filament can cause bulking to occur. Type 021N can be identified under 1000x magnification by its disk-shaped cells. It has no attached growth and no sheath. Type 021N is Gram-negative, however, it can have Gram-positive granules. This filament is thought to fit in the Thiothrix genus, however, Type 021N does not readily store sulfur. Type 021N is also more closely associated with nitrogen deficient conditions. If Type 021N grows rapidly enough, rosettes are formed. Rosettes are when multiple filaments extend around the same center point, forming an asterisk-like shape.
Unique Experience in the Field
A municipal wastewater plant in the Midwest that receives wastewater from three food companies was experiencing severe bulking and a slimy mixed liquor. They tried to treat the issues with chlorine. When this worsened the bulking, they submitted a sample to Aquafix Laboratories. When viewed microscopically, very few floc-forming bacteria were present but there was an abundance of Type 021N. By using chlorine, floc formers that normally outcompete Type 021N were being eliminated. This caused the abundance of Type 021N to increase due to its resilience to chlorination. This change caused the bacterial population in the mixed liquor to be almost entirely composed of Type 021N. Aquafix first recommended correcting the nitrogen deficiency. Ammonium nitrate was fed into the waste streams from the food facilities, and Accelerator 7 was used at the municipal plant. High amounts of incoming grease may have contributed to the municpal plant’s nitrogen deficiency. Qwik-Zyme L was added to ensure the grease was being fully broken down.
References
Jenkins, D., Richard, M.G., & Daigger, G.T. (2004). Manual on the causes and control of activated sludge bulking,
foaming, and other solids separation problems (3rd ed). CRC Press LLC.